3 mincritical
Subnet Solutions PowerSYSTEM Center (CVE-2026-63017, CVE-2026-63774)
Two critical vulnerabilities in Subnet Solutions PowerSYSTEM Center allow authenticated users on adjacent networks to bypass authorization and execute SQL injection via the report designer. CVE-2026-63017 enables low-privileged authenticated users to access admin-only resources. CVE-2026-63774 permits SQL injection through the report designer, allowing unauthorized SQL command execution. Both require authenticated adjacent-network access (CVSS v3.1 9.0).
Sens:7dConf:highAnalyzed:2026-11-05Z.ai
Authors: CISA
Source:CISA
Detection / HunterZ.ai
Immediate Actions
- Upgrade to PowerSYSTEM Center 2026 Update 1.1 or 2020 Update 30
- Disable report designer access if patching is not possible
- Disable F12 Developer Tools for Client Access Server users
- Monitor user activity records for policy violations
Key Takeaways
- CVE-2026-63017 affects PowerSYSTEM Center 2020, 2024, and 2026 product lines
- CVE-2026-63774 affects PowerSYSTEM Center 2024 and 2026 only, not 2020
- Both scored CVSS v3.1 9.0 Critical; CVSS v4.0 scores 9.4
- Neither vulnerability is remotely exploitable — adjacent network access required
- Reported by Chinmay Patel of Digital Boundary Group to CISA
Attack Chain
- Initial Access: Attacker authenticates with low-privileged account on adjacent network
- Privilege Escalation: CVE-2026-63017 exploited to access admin-level resources
- Execution: CVE-2026-63774 SQL injection via report designer executes unauthorized SQL commands
- Impact: Unauthorized data access with high confidentiality, integrity, and availability impact
Affected Systems
- PowerSYSTEM Center 2020 versions <=5.29.x
- PowerSYSTEM Center 2024 versions 6.0.x through 6.2.x
- PowerSYSTEM Center 2026 versions 7.0.x through 7.1.x
- Critical Manufacturing and Energy sector deployments
Vulnerabilities (CVEs)
| CVE | Product | Severity | Description |
|---|---|---|---|
| CVE-2026-63017 | Subnet Solutions PowerSYSTEM Center | Critical (CVSS v3.1: 9.0) | Incorrect authorization allows low-privileged authenticated user to access admin resources. |
| CVE-2026-63774 | Subnet Solutions PowerSYSTEM Center | Critical (CVSS v3.1: 9.0) | SQL injection in report designer allows authenticated user to execute unauthorized SQL commands. |
Detection Engineering Assessment
Hunting Hypotheses
| Hypothesis | Telemetry | Stage | FP Risk |
|---|---|---|---|
| Low-privileged accounts accessing admin-only resources or triggering privilege escalation events (T1068) | Application authorization logs and audit trails | Privilege Escalation | Medium — legitimate admin role changes may match |
| Authenticated user submitting SQL injection patterns through report designer requests (T1190) | Database query audit logs, WAF or application logs | Execution | Low — SQL injection patterns are anomalous |
Required Log Sources
- PowerSYSTEM Center application audit logs
- Database SQL query audit logs
- Authentication and authorization logs
- Network flow logs for adjacent segments
Control Gaps
- Application-level authorization enforcement insufficient
- Report designer input validation missing
- Lack of network segmentation allows adjacent access
Recommendations
Infrastructure Hardening
- Isolate PowerSYSTEM Center and ICS networks from business networks
- Ensure control system devices are not accessible from the internet
- Use VPN for remote access and keep VPN software updated
- Apply firewalls between adjacent network segments
User Protection
- Restrict report designer access to trusted users only
- Enforce least-privilege access for PowerSYSTEM Center accounts
- Audit low-privileged accounts for unexpected privilege escalation
MITRE ATT&CK Mapping
MITRE ATT&CK Mapping3 techniques
Tactic
Initial Access
Tactic
Privilege Escalation
Showing defanged values
- cveCVE-2026-63017Incorrect authorization allows low-privileged authenticated user to access admin resources.
- cveCVE-2026-63774SQL injection in report designer allows authenticated user to execute unauthorized SQL commands.
Related
- Siemens RUGGEDCOM CROSSBOW (CVE-2026-89196, CVE-2026-89197, CVE-2026-89198 +8 more)·2
- Hitachi Energy CoreTec Product (CVE-2026-13162, CVE-2026-43284)·1
- Mitsubishi Electric GENESIS, GENESIS64, ICONICS Suite, Hyper Historian, AnalytiX, MobileHMI, IoTWorX, MC Works64, GENESIS32 and BizViz (CVE-2023-4863, CVE-2026-16436, CVE-2026-16437 +1 more)·1