3 minmedium
Schneider Electric PowerChute Serial Shutdown (CVE-2026-13348)
Schneider Electric PowerChute Serial Shutdown v1.5 and prior lacks authentication attempt limits, enabling brute-force account takeover when redirect handling is disabled. CVE-2026-13348 (CVSS 5.3) is an improper restriction of excessive authentication attempts in PowerChute Serial Shutdown v1.5 and prior. An attacker can perform unlimited login attempts to gain unauthorized account access when redirect handling is disabled. Upgrade to v1.6 to remediate.
Sens:7dConf:highAnalyzed:2026-11-05Z.ai
Authors: Schneider Electric CPCERT, CISA
Source:CISA
Detection / HunterZ.ai
Immediate Actions
- Upgrade PowerChute Serial Shutdown to v1.6 immediately.
- Ensure redirect handling is enabled on all PowerChute deployments.
- Restrict network access to PowerChute management interfaces via firewall rules.
- Monitor for excessive failed authentication attempts against PowerChute services.
Key Takeaways
- Affects PowerChute Serial Shutdown v1.5 and prior on Windows and Linux.
- Fixed in v1.6; service auto-restarts after install, reboot required.
- Exploit requires redirect handling to be disabled on the target.
- CVSS 3.1 vector: AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N.
- Critical infrastructure sectors affected: Energy, Manufacturing, IT, Commercial Facilities.
Attack Chain
- Reconnaissance: Identify PowerChute Serial Shutdown instance with redirect handling disabled
- Initial Access: Perform unlimited authentication attempts against user accounts
- Persistence: Use compromised credentials for ongoing access to UPS management functions
Affected Systems
- Schneider Electric PowerChute Serial Shutdown v1.5 and prior (Windows)
- Schneider Electric PowerChute Serial Shutdown v1.5 and prior (Linux)
Vulnerabilities (CVEs)
| CVE | Product | Severity | Description |
|---|---|---|---|
| CVE-2026-13348 | Schneider Electric PowerChute Serial Shutdown | Medium | Allows unauthorized account access via unlimited authentication attempts when redirect handling is disabled. |
Detection Engineering Assessment
Hunting Hypotheses
| Hypothesis | Telemetry | Stage | FP Risk |
|---|---|---|---|
| High volume of failed authentication requests to PowerChute Serial Shutdown service indicates password guessing (T1110.001). | PowerChute app logs, HTTP access logs | Credential Access | Low — repeated failed logins are abnormal for UPS management interfaces. |
Required Log Sources
- PowerChute application logs
- Web server access logs
- Network flow logs
- Authentication audit logs
Control Gaps
- No rate limiting or account lockout in vulnerable versions.
- Network segmentation may not isolate UPS management interfaces.
- Application-level authentication logging may be disabled by default.
Recommendations
Infrastructure Hardening
- Isolate UPS management networks from business networks using firewalls.
- Place control system devices behind VPN for remote access.
- Disable internet exposure for all PowerChute Serial Shutdown instances.
- Apply Schneider Electric Security Handbook hardening guidelines.
User Protection
- Enforce strong passwords for all PowerChute user accounts.
- Verify no PowerChute instances remain on v1.5 or prior after upgrade.
MITRE ATT&CK Mapping
MITRE ATT&CK Mapping2 techniques
Tactic
Credential Access
Showing defanged values
- cveCVE-2026-13348Allows unauthorized account access via unlimited authentication attempts when redirect handling is disabled.